首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Potential Interference Bias in Ozone Standard Compliance Monitoring
Authors:Alan R Leston  Will M Ollison  Chester W Spicer  Jan Satola
Institution:1. Air Quality Consultant , Lebanon , CT , USA aleston@hotmail.com;3. American Petroleum Institute , Washington , DC , USA;4. Battelle Science and Technology International , Columbus , OH , USA
Abstract:Abstract

The U.S. Environmental Protection Agency has established a federal reference method (FRM) for ozone (O3) and allowed for designation of federal equivalent methods (FEMs). However, the ethylene‐chemiluminescence FRM for O3 has been replaced by the UV photometric FEM by most state and local monitoring agencies because of its relative ease of operation. Accumulating evidence indicates that the FEM is prone to bias under the hot, humid, and stagnant conditions conducive to high O3 formation. This bias may lead to overreporting hourly O3 concentrations by as much as 20–40 ppb. Measurement bias is caused by contamination of the O3 scrubber, a problem that is not detected by dry air calibration. An adequate wet test has not been codified, although a procedure has been proposed for agency consideration. This paper includes documentation of laboratory tests quantifying specific interferant responses, collocated ambient FRM/FEM monitoring results, and smog chamber comparisons of the FRM and FEMs with alternative scrubber designs. As the numbers of reports on monitor interferences have grown, interested parties have called for agency recognition and correction of these biases.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏