首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Analysis of Moisture Findings in the Interior Spaces of Finnish Housing Stock
Authors:Joseph Chelelgo  Ulla Haverinen  Mikko Vahteristo  Jari Koivisto  Tuula Husman  Aino Nevalainen
Institution:Division of Environmental Health , National Public Health Institute , Kuopio , Finland
Abstract:ABSTRACT

A grading system was developed to rate the moisture damage profile of dwellings and to study the relationship between moisture-induced indoor air problems and occupant health. A total of 630 randomly selected houses and apartments, built between 1950 and 1989, were visually inspected. Moisture observations were standardized into three damage levels. Thus, a system to classify the homes into three grades was devised. The two grades of homes associated with the highest levels of damage were graded as index homes.

Overall, 51% of the sample had some kind of moisture fault in them and one in every three homes (33%) was classified as an index home. The mean number of damage incidents in the index dwellings varied from 1.4 to 2.6. The mean number of damage incidents in the reference homes was 0.28. Prevalence of index dwellings was significantly higher (p < 0.01) in houses (38%) than in apartments (26%). There was no major difference in the prevalence of index buildings in houses built in any particular decade (30-35%). Moisture was observed in 28% of bathrooms, in 10% of kitchens, and in 17% of other spaces. Indoor relative humidity (RH) levels were low in most homes.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号