Site Redundancy in Urban Ozone Monitoring |
| |
Authors: | Alison A. Miller Thomas W. Sager |
| |
Affiliation: | 1. Texas Natural Resource Conservation Commission , Austin , Texas , USA;2. University of Texas , Austin , Texas , USA |
| |
Abstract: | This article describes two statistical methods that enable air pollution control agencies to assess the effectiveness of the spatial distribution of current stationary ozone monitoring networks by providing measures of site redundancy. These methods analyze site redundancy by determining the degree to which ozone measurements at one site can be successfully predicted from data collected at other monitoring sites. The first method, the similarity (SIM) measure, calculates redundancy based on the percentage of common operational days during which two monitoring stations report similar daily maximum ozone concentrations. The second method, a modeling technique, relates site redundancy in ozone measurement to an R-squared statistic from an autoregressive model. The model uses meteorological components recorded at a central location and ozone concentrations reported by the network’s other monitoring stations. Both techniques can assist in effective allocation of limited monitoring resources and offer a statistical approach to ambient air monitoring network design. The techniques are applied to data collected at six ozone monitoring stations in Harris County, Texas, during an eight-year period in the 1980s. The methods identified two sites in the six-site network that exhibit a high degree of redundancy. |
| |
Keywords: | |
|
|