首页 | 本学科首页   官方微博 | 高级检索  
     


Assessing Sorbents for Mercury Control in Coal-Combustion Flue Gas
Authors:Sharon Sjostrom  Tim Ebner  Trevor Ley  Richard Slye  Carl Richardson  Tom Machalek
Affiliation:1. Apogee Scientific, Inc. , Englewood , Colorado , USA ssjostrom@apogee-sci.com;3. Apogee Scientific, Inc. , Englewood , Colorado , USA;4. URS Corporation , Austin , Texas , USA
Abstract:Abstract

Sorbent injection for Hg control is one of the most promising technologies for reducing Hg emissions from power-generation facilities, particularly units that do not require wet scrubbers for SO2 control. Since 1992, EPRI has been assessing the performance of Hg sorbents in pilot-scale systems installed at full-scale facilities. The initial tests were conducted on a 5000-acfm (142-m3/min) pilot baghouse. Screening potential sorbents at this scale required substantial resources for installation and operation and did not provide an opportunity to characterize sor-bents over a wide temperature range.

Data collected in the laboratory and in field tests indicate that sorbents are affected by flue gas composition and temperature. Tests carried out in actual flue gas at a number of power plants also have shown that sorbent performance can be site-specific. In addition, data collected at a field site often are different from data collected in the laboratory, with simulated flue gas mixed to match the major components in the site’s gas. To effectively estimate the costs of Hg sorbent systems at different plants, a measure of sorbent performance in the respective flue gases must be obtained. However, injection testing at multiple facilities with large pilot systems is not practical.

Over the past five years, fixed-bed characterization testing, modeling studies, and bench-scale injection testing have been undertaken to develop a low-cost technique to characterize sorbent performance in actual flue gas and subsequently to project normalized costs for Hg removal prior to full-scale demonstration. This article describes the techniques used and summarizes field-testing results from two plants burning Powder River Basin (PRB) coal for commercial activated carbon and several other sorbent types. Full-scale projections based on the results and data collected on larger-scale systems also are included.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏