首页 | 本学科首页   官方微博 | 高级检索  
     


An Inexpensive Dual-Chamber Particle Monitor: Laboratory Characterization
Authors:Rufus Edwards  Kirk R. Smith  Brent Kirby  Tracy Allen  Charles D. Litton  Susanne Hering
Affiliation:1. School of Social Ecology , University of California at Irvine , Irvine , CA , USA;2. School of Public Health , University of California at Berkeley , Berkeley , CA , USA edwardsr@uci.edu;4. School of Public Health , University of California at Berkeley , Berkeley , CA , USA;5. Chemistry Department , Princeton University , Princeton , NJ , USA;6. Aerosol Dynamics , Berkeley , CA , USA;7. Electronically Monitored Ecosystems (EME) , Berkeley , CA , USA;8. Pittsburgh Research Laboratory , National Institute for Occupational Safety and Health Centers for Disease Control and Prevention , Pittsburgh , PA , USA;9. Aerosol Dynamics , Berkeley , CA , USA
Abstract:Abstract

In developing countries, high levels of particle pollution from the use of coal and biomass fuels for household cooking and heating are a major cause of ill health and premature mortality. The cost and complexity of existing monitoring equipment, combined with the need to sample many locations, make routine quantification of household particle pollution levels difficult. Recent advances in technology, however, have enabled the development of a small, portable, data-logging particle monitor modified from commercial smoke alarm technology that can meet the needs of surveys in the developing world at reasonable cost. Laboratory comparisons of a prototype particle monitor developed at the University of California at Berkeley (UCB) with gravi-metric filters, a tapered element oscillating microbalance, and a TSI DustTrak to quantify the UCB particle monitor response as a function of both concentration and particle size and to examine sensor response in relation to changes in temperature, relative humidity, and elevation are presented here. UCB particle monitors showed good linearity in response to different concentrations of laboratory-generated oleic acid aerosols with a coarse (mass median diameter, 2.1 µm) and fine (mass median diameter, 0.27–0.42 µm) size distributions (average r2 = 0.997 ± 0.005). The photoelectric and ionization chamber showed a wide range of responses based on particle size and, thus, require calibration with the aerosol of interest. The ionization chamber was five times more sensitive to fine rather than coarse particles, whereas the photoelectric chamber was five times more sensitive to coarse than fine. The ratio of the response between the two sensors has the potential for mass calibration of individual data points based on estimated parameters of the size distribution. The results demonstrate the significant potential of this monitor, which will facilitate the evaluation of interventions (improved fuels, stoves, and ventilation) on indoor air pollution levels and research on the impacts of indoor particle levels on health in developing countries.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号