连续流动注射间接测定空气中的五氧化二磷
引用本文:代佼,夏勇,廖德兵,王小将,陈美芳. 连续流动注射间接测定空气中的五氧化二磷[J]. 中国环境监测, 2016, 32(1): 123-127
作者姓名:代佼  夏勇  廖德兵  王小将  陈美芳
作者单位:攀枝花市环境监测站, 四川 攀枝花 617000,攀枝花市环境监测站, 四川 攀枝花 617000,攀枝花市环境监测站, 四川 攀枝花 617000,攀枝花市环境监测站, 四川 攀枝花 617000,攀枝花市环境监测站, 四川 攀枝花 617000
摘    要:建立连续流动注射间接测定空气中五氧化二磷的方法。空气中的五氧化二磷用过氯乙烯滤膜或滤筒采样,加入去离子水反应生成正磷酸,过滤、洗涤、定容后运用连续流动注射仪进行测定。优化了抗坏血酸浓度、硫酸浓度、钼酸盐浓度以及恒温室温度等影响显色的因素。最佳条件下,实际样品五氧化二磷加标回收率为96.0%~102%,相对标准偏差在4%以下;采样体积为300 L时,方法检出限为0.001 6 mg/m~3。t检验结果表明,所建方法与现行国标法的测定结果无显著性差异。方法分析速度快、重现性好、灵敏度高,适用于空气中五氧化二磷的测定。

关 键 词:空气  五氧化二磷  连续流动注射分析
收稿时间:2015-02-02
修稿时间:2015-05-20

Indirect Determination of Phosphorus Pentoxide in Air by Flow Injection Analysis
DAI Jiao,XIA Yong,LIAO Debing,WANG Xiaojiang and CHEN Meifang. Indirect Determination of Phosphorus Pentoxide in Air by Flow Injection Analysis[J]. Environmental Monitoring in China, 2016, 32(1): 123-127
Authors:DAI Jiao  XIA Yong  LIAO Debing  WANG Xiaojiang  CHEN Meifang
Affiliation:Panzhihua Environmental Monitoring Station, Panzhihua 617000, China,Panzhihua Environmental Monitoring Station, Panzhihua 617000, China,Panzhihua Environmental Monitoring Station, Panzhihua 617000, China,Panzhihua Environmental Monitoring Station, Panzhihua 617000, China and Panzhihua Environmental Monitoring Station, Panzhihua 617000, China
Abstract:A method was established for indirect determination of phosphorus pentoxide in air by flow injection analysis. The phosphorus pentoxide in air was collected by perchlorethylene filter membrane or cartridge, and then reacted with water to produce orthophosphate. The orthophosphate was analyzed by flow injection analysis after filtering, washing and constanting volume. The effects of ascorbic acid concentration, sulfuric acid concentration, molybdate concentration and thermostat temperature on the chromogenic reaction were optimized. Under the optimal conditions, the recovery rate of spiked samples was 96.0%-102% with RSD below 4%. The method detection limit was 0.001 6 mg/m3 when the sampling volume was 300 L. According to the t test, the present method showed no significant difference compared with national standard method. The present method had advantages of convenience, wide linear range, good reproducibility and high sensitivity, which was suitable for determination of phosphorus pentoxide in air.
Keywords:air  phosphorus pentoxide  flow lnjection analysis