Full scale treatment of hazardous wastewater through thermal reduction
Authors:S N Kaul  T Nandy  C V Deshpande  A Srivastava  S Shastry  L Szpyrkowicz
Institution:1. National Environmental Engineering Research Institute , Nehru Marg, Nagpur, 440020, India;2. Department of Environmental Sciences , University of Venice , Venice, Italy
Abstract:An attempt has been made to present the data relating to full scale application of evaporation‐incineration technology for containment of wastewater emanating from H‐acid (mono sodium salt of 1 amino‐8‐hydroxynapthalene 3,6‐disulphonic acid) production with recourse to zero wastewater discharge. The wastewater is acidic with high concentrations of COD and total dissolved salts and BOD/COD ratio of 0.11. NOx, SOx, SPM and CO from stack emissions are within the standards stipulated by the statutory bodies.
Keywords:H‐acid  wastewater  evaporation‐incineration  water balance  BOD/COD ratio  solid waste