首页 | 本学科首页   官方微博 | 高级检索  
     


Modified Edman degradation applied to hemoglobin for monitoring occupational exposure to alkylating agents
Authors:Jacques Mowrer  Margareta Törnqvist  Sören Jensen  Lars Ehrenberg
Affiliation:1. Department of Chemical Environmental Analysis, Wallenberg Laboratory , University of Stockholm , Stockholm, S‐106 91, Sweden;2. Department of Radiobiology , University of Stockholm , Stockholm, S‐106 91, Sweden
Abstract:A method that can be used for the monitoring of exposure to alkylating agents in the environment is presented. It is based on the quantification of alkylated N‐terminal valines in hemoglobin, using a modified Edman degradation procedure. The detection limit (GC/electron capture detector or GC/MS) is increased by two magnitudes of ten when using pentafluorophenyl isothiocyanate instead of phenyl isothiocyanate in the derivatization step. As little as one nmole N‐(—2 hydroxyethyl)valine per gram hemoglobin can be detected under practical conditions.
Keywords:Photodegradation  methyl N  N'‐dimethyl‐N‐((C‐methylcarbamoyl)‐oxy)‐l‐thiooxamimidate  photoproducts