首页 | 本学科首页   官方微博 | 高级检索  
     检索      

检测2,4-D的一次性安培型免疫传感器
引用本文:蔡强,余若祯,何苗,施汉昌.检测2,4-D的一次性安培型免疫传感器[J].环境科学,2005,26(6):169-172.
作者姓名:蔡强  余若祯  何苗  施汉昌
作者单位:清华大学环境科学与工程系环境模拟与污染控制国家重点联合实验室,北京,100084;清华大学环境科学与工程系环境模拟与污染控制国家重点联合实验室,北京,100084;清华大学环境科学与工程系环境模拟与污染控制国家重点联合实验室,北京,100084;清华大学环境科学与工程系环境模拟与污染控制国家重点联合实验室,北京,100084
基金项目:国家高技术研究发展计划(863)项目(2002AA649160);中国博士后基金(023208004)
摘    要:2,4-D是广泛使用的除草剂,以2,4-D为检测目标,研究了安培型免疫传感器.首先采用1-乙基-3-(3-二甲基氨丙基)碳二亚胺盐酸盐(EDC)作为交联剂制备2,4-D与BSA以及PLL的偶联物.用结合比1∶16的2,4-D与偶联物制备兔抗血清.免疫传感器的制备包括2个步骤,使用丝网印刷工艺制备一次性碳电极,然后通过戊二醛交联在电极表面固定2,4-D与多聚赖氨酸(PLL)的偶联物.待测水样与2,4-D抗血清和HRP酶标二抗进行间接免疫竞争反应.在HRP酶在邻苯二胺和H2O2的共同作用下发生酶促反应,检测还原电流以反映2,4-D的浓度.试验了不同浓度抗血清和酶标二抗对检测信号的影响,结果表明,2,4-D的检测下限达到1.69ng/mL,线性区间1.69~30 000ng/mL,适合饮用水中2,4-D的检测要求.

关 键 词:丝网印刷电极  2  4-D  安培型  免疫传感器
文章编号:0250-3301(2005)06-0169-04
收稿时间:2004-11-26
修稿时间:2004-11-262004-12-29

Determination of 2,4-D Using Disposable Amperometric Immunosensor
CAI Qiang,YU Ruo-zheng,HE Miao and SHE Han-chang.Determination of 2,4-D Using Disposable Amperometric Immunosensor[J].Chinese Journal of Environmental Science,2005,26(6):169-172.
Authors:CAI Qiang  YU Ruo-zheng  HE Miao and SHE Han-chang
Institution:State Key Joint Laboratory of Environmental Simulation and Pollution Control, Department of Environmental Science and Engineering, Tslnghua University, Beijing 100084, China
Abstract:2,4-Dichlorophenoxyacetic Acid (2,4-D) is the herbicide widely applied in the world. An amperometric immunosensor to detect 2,4-D was described. Firstly, 2,4-D-protein conjugate was prepared using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC). The rabbit antiserum was prepared with substitution degree of 16. Secondly, the immunosensor was fabricated using screen printing technique. The 2,4-D/PLL conjugate was immobilized on the surface of screen printed carbon electrode via crosslinking method. The free and immobilized 2,4-D competed the binding sites of anti-2,4-D antiserum. After HRP-labeled goat-anti-rabbit IgG binding with anti-2,4 antiserum, the substrate was added and current response was recorded. The dependency of concentration of antiserum and HRP-labeled anti-IgG on current response was also studied. The result shows that limit of detection for 2,4-D is 1. 69 ng/mL with linear range 1.69 - 30000 ng/mL, which reveal the potential ability to evaluate the safety of drinking
Keywords:screen printed electrode  2  4-dichlorophenoxyacetic acid  amperometric  immunosensor
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
点击此处可从《环境科学》浏览原始摘要信息
点击此处可从《环境科学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号