Institution:1. National Institute of Aerospace Technology (INTA), Torrejón de Ardoz, Spain;2. Institute of Ceramics and Glass (ICV- CSIC), Kelsen 5, 28049 Madrid, Spain;3. National Centre for Metallurgical Research (CENIM-CSIC), Av. Gregorio del Amo 8, 28040 Madrid, Spain
Abstract:A sample of 532 anhydrous ammonia nurse tanks with manufacture dates ranging from the 1950’s to 2011 were examined during 2012 by side angle ultrasound to measure the locations, sizes, and orientations of flaw indications. The indications were most frequently located on the head side of the head-to-shell welds and oriented perpendicular to the weld line in the welds’ heat affected zones. On average newer tanks had more indications than older tanks. Tanks that had been given a post-weld stress relief anneal had markedly fewer indications.
Keywords:Non-destructive inspection  Welds  Surface cracks  Stress corrosion cracking  Residual stress  Stress relief  Anhydrous ammonia  Safety