WATER QUALITY SIMULATION AND PUBLIC LAW 92–500 Case Study: Southwestern Illinois1
Authors:Nancy U Schultz  Albert Wilmarth
Abstract:ABSTRACT: Section 208 of the Federal Water Pollution Control Act Amendments of 1972 has provided the Southwestern Illinois Metropolitan and Regional Planning Commission (SIMAPC) with a unique opportunity for comprehensive planning of the region's water quality. SIMAPC initiated the 208 study by researching available technology for the analysis of point and nonpoint sources of pollution and establishing criteria by which to judge the various technniques. This led to SIMAPC'S choice of continuous simulation of stream and reservoir water quality as the most appropriate analytical tool for their needs. A continuous simulation model was calibrated and verified on three basins in the SIMPAC region. It was then used to produce load source analysis, pollution event frequency analysis, and pollution event duration analysis for ten pollutants under existing stream conditions and then under alternative future conditions. These results enabled the weighting of pollutant sources, analysis of the effectiveness of control measures, and quantitative analysis of the marginal benefit of each alternative.
Keywords:water quality planning  modeling  simulation