首页 | 本学科首页   官方微博 | 高级检索  
     检索      


RIVER DYE GAGING1
Authors:Bessel D van't Woudt  Kelvin Nicolle
Abstract:Procedures have been developed (a) to inject a tracer at a constant rate below the water surface at selected points across a stream and (b) to deal with suspended sediment. Mixing remained far from complete in relatively long channels, owing to channel and flow divergence with uncertainty where to sample downstream and which marginal sample values to include for flow calculation. These problems are encountered when mixing is largely dependent on transverse diffusion. Accurate and replicable results were obtained where dye was injected upstream and detected downstream from riffles that induced thorough turbulent mixing. Dye gaging should be practical in gorges or wherever flow is turbulent across the whole width of a channel.
Keywords:flow measurement  dye gaging  mixing in rivers
设为首页 | 免责声明 | 关于勤云 | 加入收藏