首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of alkylamine permeation through protective gloves using aliphatic amine pads
Authors:Vo E  Berardinelli S P
Institution:National Institute for Occupational Safety and Health, Division of Safety Research, 1095 Willowdale Road, Morgantown, WV 26505, USA.
Abstract:A quantitative study of alkylamine permeation through a glove material using Permea-Tec aliphatic amine pads, used for the detection of chemical breakthrough of protective clothing, was performed for triethylamine following a microwave-extraction process and gas chromatographic analysis. Triethylamine exhibited > 99% adsorption on the pads at a spiking level of 729 ng (1.0 ml). Triethylamine showed recoveries from 63 to 90% (RSD < or = 5%) over the range 0.2-1.0 ml (146-729 ng) applied to pads. The ASTM F739 standard and direct permeability testing procedures were used to determine breakthrough times for five protective glove materials using triethylamine as a challenge chemical. Breakthrough times for six protective gloves were determined ranging from 40 s to > 4 h. The quantitative concentration of triethylamine on the pads following permeation through the gloves was also determined, ranging from 101 to 103 ng cm-2 (382-386 ng per pad).
Keywords:
本文献已被 PubMed 等数据库收录!