首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Sorption of organic gases in residential rooms
Institution:1. Atmospheric Sciences Department, Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA;2. Indoor Environment Department, Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA;1. TNO Defense, Security and Safety, CBRN Protection, Lange Kleiweg 137, 2288, GJ, Rijswijk, the Netherlands;2. Emergent BioSolutions, Emergent Prod. Dev. Gaithersburg, 300 Professional Drive, Gaithersburg, MD, 20879, USA;1. Pharmacology & Toxicology, Boonshoft School of Medicine, Wright State University, 3640 Colonel Glenn Highway, Dayton, OH 45435, USA;2. Molecular Bioeffects Branch, Bioeffects Division, Human Effectiveness Directorate, 711th Human Performance Wing, Air Force Research Laboratory, Wright Patterson Air Force Base, Dayton, OH 45433, USA;1. Institutute of Chemical Defence, Changping District, Beijing 102205, PR China;2. School of Chemistry, Beijing Institute of Technology, Beijing 100081, PR China
Abstract:Experiments were conducted to characterize organic gas sorption in residential rooms studied “as-is” with furnishings and material surfaces unaltered and in a furnished chamber designed to simulate a residential room. Results are presented for 10 rooms (five bedrooms, two bathrooms, a home office, and two multi-function spaces) and the chamber. Exposed materials were characterized and areas quantified. A mixture of volatile organic compounds (VOCs) was rapidly volatilized within each room as it was closed and sealed for a 5-h Adsorb phase; this was followed by 30-min Flush and 2-h closed-room Desorb phases. Included were alkane, aromatic, and oxygenated VOCs representing a range of ambient and indoor air pollutants. Three organophosphorus compounds served as surrogates for Sarin-like nerve agents. Measured gas-phase concentrations were fit to three variations of a mathematical model that considers sorption occurring at a surface sink and potentially a second, embedded sink. The 3-parameter sink–diffusion model provided acceptable fits for most compounds and the 4-parameter two-sink model provided acceptable fits for the others. Initial adsorption rates and sorptive partitioning increased with decreasing vapor pressure for the alkanes, aromatics and oxygenated VOCs. Best-fit sorption parameters obtained from experimental data from the chamber produced best-fit sorption parameters similar to those obtained from the residential rooms.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号