引用本文:田梓, 袁放, 魏明海, 陈鸿汉, 刘菲. 硝酸根对零价铁去除地下水中六价铬的影响[J]. 环境工程学报, 2017, 11(7): 4051-4058. doi: 10.12030/j.cjee.201605240
作者姓名:田梓  袁放  魏明海  陈鸿汉  刘菲
作者单位:1.中国地质大学(北京)水资源与环境学院北京市重点实验室, 北京 100083; 2.北京中地泓科环境科技有限公司, 北京 100011
基金项目:中国地质调查局地调项目(1212011121173)
摘    要:通过批实验和连续通流的柱模拟实验对比研究了存在NO3-和不存在NO3-条件下零价铁(Fe0)去除Cr(Ⅵ)的反应特征,并对比分析了NO3-对零价铁(Fe0)去除Cr(Ⅵ)的影响。批实验结果表明,在不同初始pH条件下,NO3-的加入均使得零价铁(Fe0)去除Cr(Ⅵ)的速率升高;当初始pH=7时,NO3-的促进作用最强,反应速率是无NO3-条件下的2.1倍。柱实验结果表明,NO3-的加入使得Fe0去除Cr(Ⅵ)的反应分成了3个不同的阶段:高效期(1025 PV)。在高效期,反应中的NO3-表现为对Fe0反应位点的竞争,抑制了Cr(Ⅵ)还原。在后期的2个阶段中,反应中NO3-则呈现明显的促进作用。NO3-的存在使得零价铁(Fe0)柱趋于整体性同步钝化,延长了Fe0柱的运行寿命,并且增加了零价铁(Fe0)柱对Cr(Ⅵ)的去除效率。NO3-对Fe0去除Cr(Ⅵ)反应的促进作用原因是由于NO3-与Fe0反应产生Fe3O4,Fe3O4可以还原Cr(Ⅵ),并且具有阻滞反应的产物在Fe0表面堆积和促进电子传导作用。

关 键 词:零价铁   硝酸盐   六价铬   柱实验
收稿时间:2016-08-31

Effect of nitrate on removal of six valence chromium in groundwater by zero valence iron
TIAN Zi, YUAN Fang, WEI Minghai, CHEN Honghan, LIU Fei. Effect of nitrate on removal of six valence chromium in groundwater by zero valence iron[J]. Chinese Journal of Environmental Engineering, 2017, 11(7): 4051-4058. doi: 10.12030/j.cjee.201605240
Authors:TIAN Zi  YUAN Fang  WEI Minghai  CHEN Honghan  LIU Fei
Affiliation:1.Key Laboratory of Beijing, School of Water Resources and Environment, China University of Geosciences(Beijing), Beijing 100083, China; 2.Beijing Z. D. H. K. Environmental Science & Technology Co. Ltd., Beijing 100011, China
Abstract:The characteristics of Cr(Ⅵ) removal by zero valence iron (Fe0) in the presence or absence of NO3- were studied using batch experiments and continuous-flow column experiments. The effect of NO3- on the removal of Cr(Ⅵ) by Fe0 was studied. Batch experiment results show that the rate of removal of Cr(Ⅵ) by Fe0 (zero valent iron) was increased under different pH conditions when NO3- was present. The strongest role of NO3- in promoting chromium removal appeared when pH was 7, and the reaction rate was 2.1 times that of the reaction without NO3-. Column experiment results indicated that the process of removal of Cr(Ⅵ) by Fe0 was divided into three different stages in the presence of NO3-:a high efficiency phase (1 025 PV). During the period of high efficiency, NO3- competed for the reaction sites of Fe0 with Cr(Ⅵ) on the surface of Fe0, which inhibited the reduction of Cr(Ⅵ). In the last two stages, the NO3- showed a significant role in promoting the reduction of Cr(Ⅵ) by Fe0. The existence of NO3- made the Fe0 column tend toward overall synchronous passivation, extended the longevity of the Fe0 column, and increased the removal efficiency of Cr(Ⅵ) in the Fe0 (zero value iron) column. It was speculated that the reason for the promotion effect of NO3- in the removal reaction of Cr(Ⅵ) was due to the production of Fe3O4 during the reaction of NO- 3and Fe0. Fe3O4 not only reduced the Cr(Ⅵ) directly, but also acted as an inhibitor of the formation of passive film on the Fe0 surface, as well as an electron mediator that facilitated electron transport from Fe0 to the adsorbed Cr(Ⅵ).
Keywords:zero-valent iron  nitrate  hexavalent chromium  column experiment