首页 | 本学科首页   官方微博 | 高级检索  
     

Fe0-C微电解去除地下水中2,4-DNT的影响因素
引用本文:闫琨, 姜永海, 马志飞, 廉新颖, 徐祥健, 席北斗, 杨昱. Fe0-C微电解去除地下水中2,4-DNT的影响因素[J]. 环境工程学报, 2017, 11(6): 3381-3385. doi: 10.12030/j.cjee.201603057
作者姓名:闫琨  姜永海  马志飞  廉新颖  徐祥健  席北斗  杨昱
作者单位:1. 国家环境保护地下水污染模拟与控制重点实验室, 北京 100012; 2. 东华理工大学水资源与环境工程学院, 南昌 330013; 3. 北京师范大学环境学院, 北京 100875
基金项目:国家自然科学基金资助项目(41373129)
摘    要:采用批实验研究初始pH值、溶解氧(DO)和地下水中常见的阴、阳离子等因素对Fe0-C微电解对地下水中2,4-二硝基甲苯(2,4-DNT)去除率的影响,并分析Fe0-C降解2,4-DNT的产物。结果表明,在pH=7,DO=0.23 mg·L-1的条件下,Fe0-C去除溶液中2,4-DNT有明显的效果,反应200 min时,去除率达到83.09%,比Fe0和C的去除率提高了74.56%和9.89%;酸性条件下有利于2,4-DNT去除,初始pH=5的条件下,溶液中2,4-DNT的去除率为82%,而初始pH=10时,2,4-DNT的去除率分别为64%;反应体系中含有较高浓度的溶解氧有利于2,4-DNT的去除,在DO=9.26 mg·L-1条件下,2,4-DNT的去除率比 DO=0.23 mg·L-1时提高了9.5%;地下水中一定浓度的阴(Cl-、SO2-4)、阳离子(Ca2+、Mg2+、Na+、K+)可以提高2,4-DNT的去除率,提高率小于10%。反应过程中2,4-DNT降解的产物包括2-氨基-4-硝基甲苯(2A4 NT)、4-氨基-2-硝基甲苯(4A2 NT)和2,4-二氨基甲苯(2,4-DAT)。

关 键 词:2  4-DNT   Fe0-C微电解   地下水   去除率   影响因素
收稿时间:2016-04-27

Influencing factors of degradation of 2,4-DNT in groundwater by Fe0-C
YAN Kun, JIANG Yonghai, MA Zhifei, LIAN Xinying, XU Xiangjian, XI Beidou, YANG Yu. Influencing factors of degradation of 2,4-DNT in groundwater by Fe0-C[J]. Chinese Journal of Environmental Engineering, 2017, 11(6): 3381-3385. doi: 10.12030/j.cjee.201603057
Authors:YAN Kun  JIANG Yonghai  MA Zhifei  LIAN Xinying  XU Xiangjian  XI Beidou  YANG Yu
Affiliation:1. State Environmental Protection Key Laboratory of Simulation and Control of Groundwater Pollution, Beijing 100012, China; 2. School of Water Resources & Environmental Engineering, East China University of Technology, Nanchang 330013, China; 3. School of Environment, Beijing Normal University, Beijing 100875, China
Abstract:In this study, batch experiments were conducted to investigate the impact of initial pH, dissolved oxygen (DO), and common cations/anions on the reductive capabilities of Fe0-C for 2,4-dinitrotoluene (2,4-DNT), and the products from such a reaction were analyzed. Fe0-C removed 2,4-DNT remarkably at pH=7 and DO=0.23 mg·L-1.The removal efficiency reached 83.09% after 200 min.Compared to Fe0 and C singly, 2,4-DNT removal efficiency by the combined Fe0-C increased by 74.56%和9.89%.Acidic conditions favored the removal of 2,4-DNT.The results demonstrated that the removal rate of 2,4-DNT reached 82% when pH=5.When pH=10, the removal efficiency of 2,4-DNT was 64%.The removal rate increased 9.5% when DO increased from 0.23 mg·L-1 to 9.26 mg·L-1.Common cations and anions in groundwater influenced 2,4-DNT removal.The degradation products from 2,4-DNT reduction included 2A4 NT, 4A2 NT, and 2,4-DAT.
Keywords:2,4-DNT  Fe0-C micro-electrolysis  groundwater  removal efficiency  factors
本文献已被 CNKI 等数据库收录!
点击此处可从《环境工程学报》浏览原始摘要信息
点击此处可从《环境工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号