首页 | 本学科首页   官方微博 | 高级检索  
     检索      

上安电厂1~#炉350MW机组电除尘器改造
引用本文:戴海金.上安电厂1~#炉350MW机组电除尘器改造[J].工业安全与环保,2009,35(1).
作者姓名:戴海金
作者单位:龙净环保股份有限公司,福建龙岩,364000
摘    要:介绍了华能上安电厂1#炉电除尘器提效改造的方法,在因场地限制使得结构特殊的条件下,效率由96.8%提高到99.84%,电除尘器可靠运行已多年,为同类设备的改造提供了成功的经验.

关 键 词:电除尘器  振打  气流分布  悬伸

The Rebuilding for ESP of 350 MW Project Boiler 1# in Shang'an Power Plant
DAI Hai-jin.The Rebuilding for ESP of 350 MW Project Boiler 1# in Shang''an Power Plant[J].Industrial Safety and Dust Control,2009,35(1).
Authors:DAI Hai-jin
Institution:Longking Environmental Protection Co.;Ltd.Longyan;Fujian 364000
Abstract:This paper presents the methods of effective enhancement and rebuilding for ESP of boiler 1# in Huaneng Shang' an Power Plant.Although the ESP has a special structure for limited field,the efficiency is enhanced from 96.8% to 99.84% after the rebuilding.The ESP has been operated reliably for many years,offering a successful experience for the rebuilding of the same kinds of equipment.
Keywords:ESP rapping gas distribution overhang  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号