摘    要:介绍了华能上安电厂1#炉电除尘器提效改造的方法,在因场地限制使得结构特殊的条件下,效率由96.8%提高到99.84%,电除尘器可靠运行已多年,为同类设备的改造提供了成功的经验.

关 键 词:电除尘器  振打  气流分布  悬伸

The Rebuilding for ESP of 350 MW Project Boiler 1# in Shang'an Power Plant
DAI Hai-jin. The Rebuilding for ESP of 350 MW Project Boiler 1# in Shang'an Power Plant[J]. Industrial Safety and Dust Control, 2009, 35(1)
Authors:DAI Hai-jin
Affiliation:Longking Environmental Protection Co.;Ltd.Longyan;Fujian 364000
Abstract:This paper presents the methods of effective enhancement and rebuilding for ESP of boiler 1# in Huaneng Shang' an Power Plant.Although the ESP has a special structure for limited field,the efficiency is enhanced from 96.8% to 99.84% after the rebuilding.The ESP has been operated reliably for many years,offering a successful experience for the rebuilding of the same kinds of equipment.