Water quality supply in a Portuguese teaching hospital: monitoring and studies on detection of critical points
Authors:Pedro Norton  Joana Amaro  Natália Martins  Manuela Vieira da Silva
Institution:1. EPIUnit – Institute of Public Health, University of Porto, Porto, Portugal;2. Occupational Health Service of the Hospital Epidemiology Centre, S?o Jo?o Hospital Centre, Porto, Portugalpedro.norton@hsjoao.min-saude.pt;4. Department of Clinical Epidemiology, Predictive Medicine and Public Health, University of Porto Medical School, Porto, Portugal;5. Occupational Health Service of the Hospital Epidemiology Centre, S?o Jo?o Hospital Centre, Porto, Portugal;6. Environmental Health Department, School of Allied Health Technologies of Polytechnic Institute of Porto (ESTSP.IPP), Vila Nova de Gaia, Portugal
Abstract:Surveillance of drinking water quality is extremely important to human health, assuming greater relevance in hospital environments, especially to those individuals who are immunocompromised. This study is aimed to determine the effect of increasing free chlorine (Cl) concentration in a hospital water network in regard to water quality monitoring and microbial growth control, between 2010 and 2013 in Porto. The average of free Cl concentration in the period under analysis showed some heterogeneity per floor, varying between 0.84 and 1.25 mg/L. In addition, there was a rise in proportion of samples that exceeded WHO guidelines (free Cl ≥ 0.5 mg/L), particularly in the last two years of the same period. With respect to microbial analysis, 22.4% of the samples were positive for Legionella spp., 6.4% for Pseudomonas aeruginosa, 15% and 30.4% for aerobic plate counts at 36 and 22 ºC, respectively. The proportion of positive samples decreased throughout the period under analysis, in particular for Legionella spp. (41.7% in 2010 vs. non-detectable in 2013) and P. aeruginosa (10.8% in 2010 vs. 3.3% in 2013). These results are in accordance with the gradual rise in free Cl concentration (0.78 ± 0.94 mg/L in 2010 vs. 1.16 ± 0.51 mg/L in 2013). In conclusion, a suitable plan for drinking water quality was instituted which resulted in reducing microbiological growth in the waterwork network, improving public health protection. However, the detection of critical points associated with lower levels of free Cl were found on certain floors/points-of-use, requiring the need to improve the monitoring water treatment system and/or implementation of additional technologies.
Keywords:Water quality  hospitals  chlorine  Legionella spp    Pseudomonas aeruginosa
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号