首页 | 本学科首页   官方微博 | 高级检索  
     检索      

On-line optical determination of floc size of Fe(Ⅲ) coagulants
作者姓名:WANG Yan  GAO Bao-yu  YUE Qin-yan  ZHOU Wei-zhi  CHU Yong-bao
作者单位:School of Environmental Science and Engineering, Shandong University, Jinan 250100, China
摘    要:This study investigated the floc aggregation, average floc size, floc size variance and floc growth velocity when ferric chloride (FeCl3) and polyferric chloride (PFC) were used to treat the simulated water samples. The factors including coagulant dose, ionic strength and solution pH, which affect the floc aggregation, were studied. Experiments were carried out in a bench-scale reactor using photometric dispersion analyzer ( PDA). Results showed that there were great differences between the floc aggregation of PFC and FeCl3. The average floc size and fioc growth velocity of PFC were much larger than those of FeCl3. Compared with FeCl3, PFC gave a better coagulation performance in wider range of pH, dosage and ionic strength. It was also found that the coagulation efficiency of PFC did not depend on average floc size but on floc growth velocity.

关 键 词:废水处理    凝结剂  离子浓度  PFC
文章编号:1001-0742(2005)06-0921-04
收稿时间:2005-02-05
修稿时间:2005-03-24

On-line optical determination of floc size of Fe(III) coagulants
WANG Yan,GAO Bao-yu,YUE Qin-yan,ZHOU Wei-zhi,CHU Yong-bao.On-line optical determination of floc size of Fe(III) coagulants[J].Journal of Environmental Sciences,2005,17(6):921-925.
Authors:WANG Yan  GAO Bao-yu  YUE Qin-yan  ZHOU Wei-zhi and CHU Yong-bao
Institution:School of Environmental Science and Engineering, Shandong University, Jinan 250100, China.
Abstract:This study investigated the floc aggregation, average floc size, floc size variance and floc growth velocity when ferric chloride (FeCl_3) and polyferric chloride (PFC) were used to treat the simulated water samples. The factors including coagulant dose, ionic strength and solution pH, which affect the floc aggregation, were studied. Experiments were carried out in a bench-scale reactor using photometric dispersion analyzer (PDA). Results showed that there were great differences between the floc aggregation of PFC and FeCl_3. The average floc size and floc growth velocity of PFC were much larger than those of FeCl_3. Compared with FeCl_3, PFC gave a better coagulation performance in wider range of pH, dosage and ionic strength. It was also found that the coagulation efficiency of PFC did not depend on average floc size but on floc growth velocity.
Keywords:coagulants  photometric dispersion analyzer(PDA)  floc aggregation  water treatment
本文献已被 CNKI 维普 PubMed 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号