压力脉冲波法天然气管道堵塞检测研究
引用本文:李清平,储佳伟,姚海元,庞维新,吕鑫,刘瑜,宋永臣,赵佳飞. 压力脉冲波法天然气管道堵塞检测研究[J]. 中国安全生产科学技术, 2021, 17(7): 5-9. DOI: 10.11731/j.issn.1673-193x.2021.07.001
作者姓名:李清平  储佳伟  姚海元  庞维新  吕鑫  刘瑜  宋永臣  赵佳飞
作者单位:(1.天然气水合物国家重点实验室,北京 100027;2.中海石油有限公司北京研究中心,北京 100027;3.大连理工大学 能源与动力学院,辽宁 大连 116024)
基金项目:* 基金项目: 国家科技重大专项项目(2016ZX05028-004-004)
摘    要:为快速检测出天然气管道堵塞位置、长度及堵塞程度,解决天然气输运管道中堵塞定位难题,探讨压力脉冲波法管道堵塞检测的可行性与效果.搭建长220 m的压力脉冲波堵塞检测实验系统,进行多组连续性长堵塞检测实验和水堵检测实验.结果表明:连续性长堵塞检测实验中堵塞前沿反射信号为负压波,堵塞后沿信号为正压波,且波形清晰可辩,其多组实...

关 键 词:水堵  管道堵塞  堵塞检测  压力脉冲波  天然气

Study on pressure pulse wave method for blockage detection in gas pipelines
LI Qingping,CHU Jiawei,YAO Haiyuan,PANG Weixin,LYU Xin,LIU Yu,SONG Yongchen,ZHAO Jiafei. Study on pressure pulse wave method for blockage detection in gas pipelines[J]. Journal of Safety Science and Technology, 2021, 17(7): 5-9. DOI: 10.11731/j.issn.1673-193x.2021.07.001
Authors:LI Qingping  CHU Jiawei  YAO Haiyuan  PANG Weixin  LYU Xin  LIU Yu  SONG Yongchen  ZHAO Jiafei
Affiliation:(1.State Key Laboratory of Natural Gas Hydrate,Beijing 100027,China;2.Beijing Research Center of CNOOC Co.,Ltd.,Beijing 100027,China;3.School of Energy and Power Engineering,Dalian University of Technology,Dalian Liaoning 116024,China)
Abstract:To rapidly detect the location,length and degree of the blockage in natural gas pipelines,and solve the problem of blockage location in the natural gas transportation pipelines,the feasibility and effect of the pressure pulse wave method for blockage detection were discussed.A 220 m long experimental system of the pressure pulse wave for blockage detection was established,and multiple groups of continuous long blockage detection and water blockage detection tests were conducted.The results showed that in the continuous long blockage detection tests,the reflected signal of blockage frontier was the negative pressure wave,while the signal of blockage back was the positive pressure wave,and the waveform was clear and identifiable.The average detection errors of the blockage location,blockage length and blockage rate in multiple groups of tests were 0.23%,0.75% and 2.67%,respectively.In the water blockage detection tests,the reflected signals were clear,but the waveform was complex,and the average detection errors of blockage location,blockage length and blockage rate were 0.78%,9.61% and 43.28%,respectively.The experimental results effectively validated the reliability and feasibility of the pressure pulse wave method,and it provide guidance for the on-site application of pressure pulse wave method for blockage detection.
Keywords:water blockage   blockage in pipeline   blockage detection   pressure pulse wave   natural gas
本文献已被 CNKI 等数据库收录!
点击此处可从《中国安全生产科学技术》浏览原始摘要信息
点击此处可从《中国安全生产科学技术》下载免费的PDF全文