首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An alternative to additional SO3 injection for fly ash conditioning
Authors:Bayless D J  Khan A R  Tanneer S  Birru R
Institution:Department of Mechanical Engineering, Ohio University, Athens, USA. bayless@ohio.edu
Abstract:Small concentrations, approximately 2-10 parts per million (ppm), of injected sulfur trioxide (SO3) have improved particulate collection efficiencies of electrostatic precipitators burning lower-sulfur coal. However, the addition of extra SO3 not only incurs costs but also presents negative environmental effects. This work explored a method that could be applied to existing coal-fired power plants to convert the sulfur dioxide (SO2) already present in the flue gas to sufficient levels of SO3 for fly ash conditioning as an alternative to adding SO3 by burning elemental sulfur. During this research, a pre-mixed natural gas flame was used to promote the conversion of SO2 to SO3 in a drop-tube furnace with average non-flame, free stream gas temperatures of 450 and 1000 K. SO3 concentrations measured by wet chemistry and confirmed using elemental balances of other sulfur species measured by gas chromatography revealed that as much as 7% of SO2 was homogeneously transformed to SO3. The results also showed that at low temperatures, the rate at which SO3 is converted back to SO2 decreased, thus extending the time period during which SO3 concentrations would be sufficient for ash conditioning. An additional benefit of this technique is speculated to result from increased flue gas humidity.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号