San copolymer membranes with ion exchangers for Cu(II) removal from synthetic wastewater by electrodialysis |
| |
Authors: | Simona Caprarescu Mihai Cosmin Corobe Violeta Purcar Catalin Ilie Spataru Raluca Ianchis Gabriel Vasilievici Zina Vuluga |
| |
Affiliation: | 1 “Politehnica” University of Bucharest, Faculty of Applied Chemistry and Materials Science, Department of Inorganic Chemistry, Physical Chemistry and Electrochemistry, Calea Grivitei, no. 132, 010737, Bucharest, Romania;2 National Research and Development Institute for Chemistry and Petrochemistry — ICECHIM, Polymer Department, Splaiul Independentei, no. 202, 060021, Bucharest, Romania |
| |
Abstract: | Heterogeneous membranes were obtained by using styrene-acrylonitrile copolymer (SAN) blends with low content of ion-exchanger particles (5 wt.%). The membranes obtained by phase inversion were used for the removal of copper ions from synthetic wastewater solutions by electrodialytic separation. The electrodialysis was conducted in a three cell unit, without electrolyte recirculation. The process, under potentiostatic or galvanostatic control, was followed by pH and conductivity measurements in the solution. The electrodialytic performance, evaluated in terms of extraction removal degree (rd) of copper ions, was better under potentiostatic control then by the galvanostatic one and the highest (over 70%) was attained at 8 V. The membrane efficiency at small ion-exchanger load was explained by the migration of resin particles toward the pores surface during the phase inversion. The prepared membranes were characterized by various techniques i.e. optical microscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis and differential thermal analysis and contact angle measurements. |
| |
Keywords: | SAN copolymer Membrane Ion exchange Copper ions Electrodialysis Wastewater treatment |
本文献已被 万方数据 等数据库收录! |
| 点击此处可从《环境科学学报(英文版)》浏览原始摘要信息 |
|
点击此处可从《环境科学学报(英文版)》下载全文 |
|