地震台站的雷害和防雷技术及其应用 |
| |
引用本文: | 曲明,肖洪财. 地震台站的雷害和防雷技术及其应用[J]. 防灾减灾工程学报, 2000, 0(4) |
| |
作者姓名: | 曲明 肖洪财 |
| |
作者单位: | 徐州地震台!江苏徐州221008(曲明),江苏省地震局!江苏南京210014(肖洪财) |
| |
摘 要: | 浅析了地震台的雷害。根据各台站实际情况调研了区域防雷、通信传输线防雷、电源防雷及传感器防雷等多方面的技术 ,不同台站采用不同的防雷技术。并以雷害严重的高邮台为例 ,具体介绍了其防雷系统的设计和施工。
|
关 键 词: | 地震台站 雷害 防雷技术 |
THUNDER DISASTER AND APPLICATION OF ITS DEFENCE TECHNIQUE TO SEISMOLOGICAL STATION |
| |
Abstract: | The thunder disasters of seismological stations are briefly analysed Based on the practical cases of different station, the various techniques of thunderproof for region, communication transitional line Power supply and sensor are researched The different thunderproof techniques are applied to various station. Finally, The Gaoyou station subjected to serious thunder disaster is cited as an example, the design and construction of thunderproof system are presented |
| |
Keywords: | Seismdogical station thunder disaster thunderproof technig` |