Organic dust and gaseous contaminants at wood working shops
Authors:Abdel Hameed A A  Khoder M I  Farag S A
Institution:Air Pollution Department, National Research Centre, Dokki, Giza, Egypt.
Abstract:Airborne dust bioaerosols, ammonia and formaldehyde levels were determined inside two different (ventilated and unventilated) wood working shops. Airborne dust was found at mean values of 4.3 and 3.01 mg m(-3). These levels were higher than that recommended by Egyptian environmental law 1 mg m(-3) indoor maximum allowable concentration (MAC) for hard wood]. The highest frequency of aerodynamic size distribution of airborne wood dust was detected at a diametre of 4.9 microm which was recorded during a machining operation. Total viable bacteria were recorded at a mean value of 10(4) colony-forming units (cfu) m(-3), whereas Gram-negative bacteria were found at very low counts (10(1) cfu m(-3)). Fungi levels were recorded at mean values of 10(3) and 10(2) cfu m(-3) in ventilated and unventilated shops, respectively. Penicillium, Aspergillus, Cladosporium and yeast species were dominant isolates. Moreover, actinomycetes were found at a mean value of 10(3) cfu m(-3) at both workshops. Ammonia was detected in relatively low concentrations (mean values of 457 and 623 microg m(-3)), whereas formaldehyde was found in relatively moderate concentrations (mean values of 0.42 and 0.64 ppm).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏