LAKE QUALITY DISCRIMINANT ANALYSIS1
Authors:Kenneth Reckhow
Abstract:ABSTRACT: Despite the fact that lake phosphorus loading criteria have proven to be valuable tools in lake management, they are generally subjective in nature or incomplete in form. In order to address these shortcomings, the oxic-anoxic transition point was selected as an objective quality criterion and discriminant analysis was used to construct a lake classification function. This function is dependent upon lake phosphorus loading, mean depth, and overflow rate. The value of the function may be expressed as a probability of classification (as either oxic or anoxic). When used in prediction, inclusion of the input error permits the estimation of the change in classification probability as input uncertainty is reduced. Further, the form of the discriminant function suggests that the annual volumetric loading is a more informative term for the expression of phosphorus loading than is the annual areal loading.
Keywords:discriminant analysis  lakes  eutrophication  phosphorus  dissolved oxygen  water quality management