首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Sudden high concentration of TSP affected by atmospheric boundary layer in Seoul metropolitan area during duststorm period
Authors:Choi H  Zhang Y H  Kim K H
Institution:Department of Atmospheric Environmental Sciences, Kangnung National University, Gangneung, Gangwondo 210-702, Republic of Korea. du8392@hanmail.net
Abstract:Hourly concentrations of TSP, PM(10), PM(2.5) near the surface at Seoul city were examined from March 20 to March 25, 2001 (duststorm event) in order to investigate the effect of a duststorm generated in China on the local aerosol concentration in Korea, The ratios of fine to coarse particles such as TSP to PM(10), TSP to PM(2.5) and PM(10)-PM(2.5) to PM(2.5) showed that a great amount of dust transported from the origin of the duststorm was remarkable with a maximum ratio of 9.77 between TSP and PM(2.5). Back trajectories every 6 h showed the movement of dust particles in the lower atmosphere near 500 m to 1500 m (atmospheric boundary layer), which implied transport from Baotou in inner Mongolia of northern China to the direction of Seoul city in Korea and then the back trajectories passed near the southern border of Mongolia and Baotou through Zengzhou in the midlevels (3000 m) and low levels (500 m) of China, finally reaching Seoul city. So, the TSP concentration at Seoul city was partially influenced by the duststorm, under the prevailing westerly wind and the transported aerosols could influence high concentrations of pollutants of TSP, PM(10) and PM(2.5) in Seoul. The sudden high concentrations of TSP and PM(10) were found for a few hours, especially at 1500 to 1800 LST, March 22. At 1200 LST, before the passage of a cold front through the Korean peninsula, the convective boundary layer (CBL) near Seoul was not shallow, but at 1500 LST, under the frontal passage, the CBL was remarkably thinner (less than 300 m), due to the compression of the boundary layer by the intrusion of cold air. This resulted in the increase of the TSP concentration, even though the mixed layer above maintained almost the same depth. At 1800 LST shortly after the frontal passage, that is, near sunset, the nocturnal cooling of the ground caused air parcels to cool, thereby enhancing the shallower nocturnal surface inversion layer and producing the maximum concentration of TSP of 1388 microg/m(3) near Seoul city.
Keywords:TSP  PM10  PM2  5  Dust storm  Convective boundary layer  Frontal passage
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号