摘    要:介绍储运分公司北方输油站队,通过选用安全、防爆的数字显示温度控制器等技术手段,对储罐区消防给水管网裸露阀门及连接管段的防冻处理,实现冬季消防稳高压系统正常运行的施工工艺,并详细介绍了防爆数字显示温度控制器的工作原理及施工步骤。

关 键 词:防爆  温度控制器  保温  稳高压

Discussion on Steady High Pressure System Operation of Oil Transport Station in Winter
Zhao Shuqing. Discussion on Steady High Pressure System Operation of Oil Transport Station in Winter[J]. Safety Environment Health, 2010, 10(11): 43-44. DOI: 10.3969/j.issn.1672-7932.2010.11.017
Authors:Zhao Shuqing
Affiliation:Zhao Shuqing (SINOPEC Pipeline and Storage Sub-company Weifang Department Dongying Station, Shandong, Dongying, 257067)
Abstract:This paper introduces some measures to realize safe operation of the steady high pressure system in northern oil transport station by choosing safe and explosion-proof LED temperature controller and frozen proof measure for the fire fighting pipe and valves. And, it discusses explosion-proof LED temperature controller theory and installation procedures.
Keywords:explosion proof   temperature controller   insulation   steady high pressure