首页 | 本学科首页   官方微博 | 高级检索  
     


Radial diffusive sampler for the determination of 8-h ambient ozone concentrations
Authors:Plaisance H  Gerboles M  Piechocki A  Detimmerman F  de Saeger E
Affiliation:Laboratoire Central de Surveillance de la Qualité de l'Air, Ecole des Mines de Douai, Département Chimie et Environnement, 941 rue Charles Bourseul, Douai, France.
Abstract:The 8-h ozone radial diffusive sampler was evaluated according to the CEN protocol for the validation of diffusive samplers. All the parameters regarding the sampler characteristics were found to be consistent with the requirements of this protocol apart from the blank value, which must be evaluated and subtracted at each sampling. The nominal uptake rate was determined in laboratory conditions. However, the uptake rate depends on the mass uptake, temperature, humidity and on the combination of temperature and humidity. Based on laboratory experiments, an empirical model has been established which improved the agreement between the radial sampler and the reference method. This improvement was observed under several different meteorological and emission conditions of sampling. By using the model equation of uptake rate, the data quality objective of 30% for the expanded uncertainty included in the O(3) European Directive, is easily attained. Therefore, the sampler represents an appropriate indicative method.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号