Abstract: | ABSTRACT: The empirical fit of an annual harmonic function to stream temperature measurements in central New England can be improved by considering a harmonic period of less than 365 days instead of 365 or 366 days. Generalized equations, developed using periodic temperature data from 27 streamflow stations, allow predictions of stream temperature at any site given (1) the mean basin altitude (E), in meters above mean sea level, and (2) station latitude (LAT), in degrees. Stream temperature t, in degrees Celsius, on day number d, in days starting with January 1, is estimated as: in which, M = 31.48 – 0.0025 (E) ? 0.4635 (LAT) with standard error of estimate of 0.62°C, and τ= 1228.88 – 21.01 (LAT) with standard error of estimate of 14.1 days. |