A test for electrical ignitions of flammable dust clouds
Affiliation:1. NS3E «Nanomatériaux pour des Systèmes Sous Sollicitations Extrêmes» UMR 3208 ISL/CNRS/UNISTRA, French-German Research Institute of Saint-Louis, 5 rue du Général Cassagnou, Saint-Louis, France;2. IS2M «Institut de Science des Matériaux de Mulhouse» UMR 7361 CNRS, 15 rue Jean Starcky, 68057 Mulhouse, France
Abstract:The Atex Directive specifically includes the explosion hazards arising from the presence of flammable dusts. The European standards body CENELEC proposed a research project to develop tests for assessing the ignition hazard due to electrical apparatus used in hazardous dusty environments. This paper describes the work done on developing a test for electrical spark ignitions of explosive dust atmospheres. A prototype apparatus incorporating the dust explosibility vertical tube and the STA break flash apparatus has been developed. Tests using three dusts showed sulphur dust had ignition characteristics close to those of gas Group B, while other dusts were much less easily ignitable than methane. Round robin tests using a duplicate apparatus and the proposed test method produced results very close to those obtained using the original apparatus.
Keywords:
本文献已被 ScienceDirect 等数据库收录!