首页 | 本学科首页   官方微博 | 高级检索  
     检索      

萘乙二胺偶氮光度法测定苯胺的探讨
引用本文:刘红涛,吴孟李.萘乙二胺偶氮光度法测定苯胺的探讨[J].环境工程,2001,19(1):49-50.
作者姓名:刘红涛  吴孟李
作者单位:广东省珠海市城市排水监测站,
摘    要:试验了萘乙二胺偶氮光度法测定苯胺的反应。结果表明 ,显色温度在 2 5℃ ,显色时间为 40min ,通过标样分析 ,相对误差为 - 0 2 %。对 4个废水水样进行测定结果表明 ,回收率在 97%~ 10 2 %之间。

关 键 词:苯胺  萘乙二胺  分光光度法  温度  时间

THE DISCUSSION OF THE DETERMINATION OF ANILINES BY SPECTROPHOTOMETRY WITH N(1-NAPHTHYL)-ETHYLENEDIAMINE
Liu Hongtao et al.THE DISCUSSION OF THE DETERMINATION OF ANILINES BY SPECTROPHOTOMETRY WITH N(1-NAPHTHYL)-ETHYLENEDIAMINE[J].Environmental Engineering,2001,19(1):49-50.
Authors:Liu Hongtao
Abstract:The determination of anilines by spectrophotometry with N (1 Naphthyl) ethylenediamine was tested.The results showed that the developed temperature was at 25℃,the developed time was 40 minutes and the results were satisfactory.The relative error was -0.2% by analysis of standard sample and the recovery was 97%~102% by determination of four waste water samples.
Keywords:anilines  N  (1  Naphthyl)  ethylenediamine  spectrophotometry  temperature and time  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号