首页 | 本学科首页   官方微博 | 高级检索  
     检索      

固相萃取-高效液相色谱法测定水中苯胺研究
引用本文:闫海霞.固相萃取-高效液相色谱法测定水中苯胺研究[J].环境科学与管理,2014,39(12):145-146.
作者姓名:闫海霞
作者单位:呼和浩特市环境监测中心站,内蒙古呼和浩特,010030
摘    要:采用固相萃取-高效液相色谱法对水中苯胺含量进行定性、定量分析.结果显示:苯胺含量在2 mg/L∽ 50 mg/L之间呈良好线性关系,回归方程为Y=8.852 5X-3.174 4,相关系数为0.99964,最低检出限为0.1mg/L,样品加标回收率在72.42% ∽78.65%之间,相对标准偏差(RSD)为2.53% ∽4.11% (n =7).该方法操作简便、快捷,是水中苯胺含量快速而准确的检测方法.

关 键 词:固相萃取  高效液相色谱  苯胺

Determination of Aniline in Water by SPE-HPLC Method
Yan Haixia.Determination of Aniline in Water by SPE-HPLC Method[J].Environmental Science and Management,2014,39(12):145-146.
Authors:Yan Haixia
Institution:Yan Haixia ( Hohhot Environmental Monitor Center, Hohhot 010030, China)
Abstract:SPE - HPLC method was used to analyses aniline in water qualitatively and quantitatively. It was shown that good linear relationship ranged from 2 to 50 rag/L, with a correlation coefficient of 0. 999 64. The limit of quantitation was 0. 1 mg/L. The recoveries ranged from 72.42% to 78.65%. Relative standard deviation ranged from 2. 53% to 4. 11%. The method is sim- ple and quick operation. It is an accurate and stable method to detect the content of aniline in water.
Keywords:solid phase extraction  high performance liquid chromatography  aniline
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号