首页 | 本学科首页   官方微博 | 高级检索  
     


Operating characteristics of a fabric filter on a peaking/cycling boiler without auxiliary preheat or reheat
Authors:Walter Smit  Kirk Spitzer  
Abstract:A fabric filter has been on-line for one year on a coal-fired boiler that is primarily a peaking unit within the power schedule. For the first six months, Eastern Kentucky coal with 2.5% sulfur was the fuel source for 30% of the time, with low-sulfur Montana coal constituting the remaining fuel during the operation period. Bag life has been excellent with no bag failures reported to date, and the pressure drops have been low. There has never been an auxilliary heat source to preheat the fabric filter for start-up, nor to reheat the fabric filter when operating at reduced load with associated low back-end temperatures. Conclusions are that the filter cake formed does protect the bags from blinding at low load conditions, and a special acid-resistant finish applied to the glass fibers protects the bags when high-sulfur coal is burned at low temperatures. Overall, this installation provides an excellent data base for cycling service and high-sulfur coal usage with a fabric filter.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号