电站锅炉水冷壁爆管原因分析及对策
引用本文:王新良,马国伟.电站锅炉水冷壁爆管原因分析及对策[J].防灾减灾工程学报,2016(4):50-54.
作者姓名:王新良  马国伟
作者单位:国电科学技术研究院, 宁夏 银川 750011
摘    要:针对某电站锅炉水冷壁严重高温腐蚀,发生爆管事故问题,采用宏观检查、金相及沉积物能谱分析等方法,找出导致水冷壁大面积高温腐蚀的影响因素,提出了改进和预防措施。应用结果结果表明:燃烧器改造及锅炉燃烧调整,使水冷壁爆管事故得到有效控制,确保了锅炉安全稳定运行。

关 键 词:电站锅炉    水冷壁    高温腐蚀    爆管

Cause analysis and countermeasures on boiler water wall tube explosion in power plant
WANG Xinliang,MA Guowei.Cause analysis and countermeasures on boiler water wall tube explosion in power plant[J].Journal of Disaster Prevent and Mitigation Eng,2016(4):50-54.
Authors:WANG Xinliang  MA Guowei
Institution:State Power Science and Technology Research Institute, Yinchuan Ningxia 750011 , China
Abstract:Aiming at the accident of water wall tube explosion causing by high- temperaturecorrosion happening in a boiler of power plant, By the methods of macroscopic inspection,metallographic analysis and sediment energy spectrum analysis, finds out the influence factors of hightemperature corrosion of water wall tubes corrosion, brings forward prevention measure. Theapplication result shows that burner improvement and boiler combustion adjustment can controlavailably the the accident of water wall tube explosion and ensure the safe and steady operation of theboiler.