首页 | 本学科首页   官方微博 | 高级检索  
     


Ion exchange treatment of rinse water generated in the galvanizing process.
Authors:Elena Mara?ón  Yolanda Fernández  Leonor Castrillón
Affiliation:Department of Chemical and Environmental Engineering, Higher Polytechnic School of Engineering, University of Oviedo, Gijon, Spain. emara@uniovi.es
Abstract:A study was conducted of the viability of using the cationic exchange resins Amberlite IR-120 and Lewatit SP-112 to treat rinse water generated in the galvanizing process as well as acidic wastewater containing zinc (Zn) and iron (Fe). Solutions containing either 100 mg/L of Zn at pH 5.6 (rinse water) or Fe and Zn at concentrations of 320 and 200 mg/L at pH 1.5 (acidic water), respectively, were percolated through packed beds until the resins were exhausted. Breakthrough capacities obtained ranged between 1.1 and 1.5 meq metal/mL resin. The elution of metal and the regeneration of resins were performed with hydrochloric acid. The influence of the flowrate used during the loading stage was also studied, with 0.5 bed volumes/min (3.2 cm/min) found to be the optimum flowrate.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏