首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Magnetisch abgeschirmte Kabine zur Aufnahme kleinster magnetischer und elektrischer Biosignale
Authors:Albrecht Mager
Institution:1. Rodenbach bei Hanau, freier Mitarbeiter der Vacuumschmelze GmbH Hanau, D-6458, Deutschland
Abstract:An extraordinary magnetically shielded room was designed and constructed for the Physikalisch-Technische Bundesanstalt Institut Berlin to measure extremely weak magnetic fields of the human body with SQUID-magnetometers. The inner and the outer dimensions of the cube-shaped room are 2.25 m and about 5 m. The shield has 6 magnetic shells of a high-permeability alloy and an inner shell welded of massive copper plates. The total weight of the magnetic alloy is about 10 t and about 5 t for the inner copper shell. The required shielding factor of 1000 for the very low frequencies was greatly surpassed by the real measured value of 10000 (measured without any compensating or idealizing method). With rising frequencies the shielding factor reaches higher values, at 50 Hz more than 100000 and a million for 1000 Hz. First measurements in the shielded room with high-resolution magnetocardiograms (HR MCG) and high-resolution electrocardiograms (HR ECG) showed new methods for non-invasive electrophysiological investigations in man.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏