摘    要:研究了用高效毛细管电泳对自来水水样中常见金属离子的快速测定方法。结果表明,K+、Na+、Li+、Ca2+、Mg2+、Ba2+、Sr2+7种离子在8 min内可全部分离,回收率为98.0%~103.3%。峰面积和迁移时间的相对标准偏差分别在3.2%和1.1%以下,重现性较好,具有较高的检测灵敏度。

关 键 词:高效毛细管电泳  碱金属  碱土金属

Rapid Determination of Familiar Electropositive Ion in Water Sample
ZHU Ze-hua.Rapid Determination of Familiar Electropositive Ion in Water Sample[J].Arid Environmental Monitoring,2010,24(1):55-57.
Authors:ZHU Ze-hua
Institution:Jiangsu Environmental Monitoring Center;Nanjing Jiangsu 210036;China
Abstract:The paper studied rapid determination method of familiar eleetropositive ion in water supply sample with effective capillary eleetrophoresis. The result showed seven kinds ion including K^+、Na^+、Li^+、Ca^2+、Mg^2+、Ba^2+、Sr^2+ were entirely separated within 8 minutes, recovery ratio was from 98.0% to 103.3%. Standard deviation kurtosis area and migratory time were respectively 3.2% and 1.1%, fidelity was good, and this method had good determination sensitivity.