摘    要:磷钼蓝法测定水中总磷,所用的抗坏血酸溶液很不稳定,只能保存数周。为延长抗坏血酸溶液的有效使用时间,节约试剂、提高工作效率,提出改进抗坏血酸溶液的配制方法,即在配制抗坏血酸溶液时,加入适量的EDTA和冰乙酸。经实验,该溶液贮于棕色玻璃瓶,放在冰箱中可稳定3个月,使用效果符合测定要求。

关 键 词:抗坏血酸溶液 配制方法 水质监测 磷钼蓝法
文章编号:1006-2009(2001)06-0039-02
修稿时间:2001-09-27

Improvementabout Ascorbic Acid Solution Make-up Method
JIN Zhong hua. Improvementabout Ascorbic Acid Solution Make-up Method[J]. The Administration and Technique of Environmental Monitoring, 2001, 13(6): 39-40
Authors:JIN Zhong hua
Abstract:When determining TP of water using Phosphorus Molybdenum Blue Method, ascorbic acid solution was unstable, can only be kept for several weeks. To prolong the effective usage time of ascorbic acid solution and to save reagent, the make up method to improve ascorbic acid solution was suggested, as to add appropriate EDTA and glacial acetic acid. During experiment, the maintenance time of ascorbic acid solution sealed in brown glass bottle can achieve 3 months in refrigeration.