Monitoring Biofilm Thickness Using A Non-Destructive, On-Line, Electrical Capacitance Technique |
| |
Authors: | R. Maurício C. J. Dias F. Santana |
| |
Affiliation: | (1) Dep. de Ciências e Engenharia do Ambiente, Universidade Nova de Lisboa – Faculdade de Ciências e Tecnologia, Quinta da Torre, 2829-516, Monte da Caparica, Portugal;(2) Dep. de Ciências dos Materiais, Universidade Nova de Lisboa – Faculdade de Ciências e Tecnologia, Quinta da Torre, 2825, Monte da Caparica, Portugal |
| |
Abstract: | Abstact The present study was designed to evaluate indirect, non-invasive, on-line measurement of biofilm thickness using an electrical capacitance technique. Several assays were carried out and the results showed that, at a frequency of 1 kHz, electrical capacitance could be used to measure biofilm thickness indirectly (with a correlation coefficient of 0.9495). The reproducibility revealed by the assays was also highly satisfactory.However, in contrast to what was expected, there was an inverse relationship between electrical capacitance and biofilm thickness, i.e. electrical capacitance diminished with the increase in the biofilm thickness.The tests were also carried out at different frequencies (1 kHz, 10 kHz and 100 kHz) |
| |
Keywords: | electrical capacitance biofilm thickness non-destructive technique on-line measurement |
本文献已被 PubMed SpringerLink 等数据库收录! |
|