首页 | 本学科首页   官方微博 | 高级检索  
     检索      


ESP Bus Section Failures: Design Considerations
Authors:Louis Theodore  Joseph Reynolds
Institution:Manhattan College , Riverdale , New York , USA
Abstract:This paper addresses a common operation and maintenance problem encountered with sectionalized electrostatic precipitators—bus section failure. ESPs are normally designed to meet a specific minimum collection efficiency in order to comply with emission standards; the loss of several bus sections may cause the unit to be out of compliance. In this paper, the effect of bus section failure on precipitator performance is analyzed. The study is presented in two parts. First, a simplified procedure to estimate the effect of bus section failure on the overall collection efficiency is developed. An illustrative example is presented to demonstrate the use of the technique. Secondly—and this is the main thrust of this study—the technique is extended to include calculations on whether a unit is out of compliance due to the failure of a given number of bus sections. This development clearly shows that this latter effect can only be expressed in terms of a probability. Two additional examples, based on a field unit using actual test data, complement the presentation and illustrate this probability calculation.