A High-Volume Sampler for the Determination of Particle Size Distributions in Ambient Air
Authors:David M. Bernstein  Michael T. Kleinman  Theo. J. Kneip  Tai L. Chan  Morton Lippmann
Affiliation:Institute of Environmental Medicine New York University Medical Center
Abstract:A size selective particle sampler has been developed for continuous sampling of the urban aerosol over periods ranging from hours to weeks, providing relatively large sample weights. The system, which is now operating in New York City, uses a parallel array of two-stage samplers. The cyclones used as the first stage collectors have 50% particle retention at 3.5,2.5,1.5 and 0.5 µm aerodynamic diameter, respectively. Undersize particles which pass through the cyclones are captured on glass fiber filters. Equal intake velocities are assured by using flow equalizers on the inlets to the cyclones. Accurate control of the flow through the cyclones is obtained by the use of an integrated circuit pressure transducer in conjunction with a specially designed feedback control circuit. The collection efficiencies of the cyclone were calibrated using monodisperse ferric oxide test aerosols tagged with Tc-99m. Mass balances of the par-ticulates collected on the cyclones and filters are obtained for the five sampling stages. Preliminary results show the distributions of the total suspended particulates in New York City to be bimodal. The distributions of lead, copper, and manganese with particle size are also discussed.