The Collection and Analysis of Inorganic Dust Downwind of Source Effluents
Authors:A E Alcocer  L B Potter  M Feldstein  H Moore
Institution:1. Bay Area Air Pollution Control District , San Francisco , USA;2. Department of Public Health , Air and Industrial Hygiene Laboratory , Berkeley , USA
Abstract:Two directionally oriented high-volume samplers are used to pinpoint the collection of specific inorganic dusts from an industrial emission. One of the samplers is placed upwind of the source, and the other downwind. Both samplers are activated by winds blowing from the direction of the source to the downwind sampler. Both are de-activated when the wind shifts from the 30° sampling arc. Thus, the upwind sampler “sees” background dust, and the downwind sampler “sees” material originating from the source. Microsorban filters are used to collect the dust materials. The filter is then dissolved in benzene and the residue washed with benzene to remove the filter material and organic substances collected. The residue consists of dry, inorganic dust, which is then subjected to X-ray diffraction and optical microscopy, for analysis. This technique was successfully used to collect and analyze cement dust and mica dust from two separate industrial sources. The technique has promise for the analysis of a wide variety of inorganic materials which can be identified by X-ray diffraction, optical microscopy or other techniques.