首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A Comparison Study of Various Types of Ozone and Oxidant Detectors Which Are Used for Atmospheric Air Sampling
Authors:Irving Cherniack  Robert J Bryan
Institution:1. Principal Engineer Director of Technical Services , Los Angeles County Air Pollution Control District , Los Angeles , California , USA;2. Director of Technical Services , Los Angeles County Air Pollution Control District , Los Angeles , California , USA
Abstract:Four continuous automatic analyzers for measurement of atmospheric levels of ozone were used in a calibration and field study. These were (1) a colorimetric instrument based upon detection of iodine released from neutral potassium iodide reagent, {2) a coulometric instrument utilizing the polarization current as a measurement of iodine released by ozone in a cell contacted by potassium iodide reagent, (8) a galvanic cell measuring bromine release by ozone, and (4) an ultraviolet photometer. Some ozone determinations by the manual rubber cracking procedure were included. After calibration with ozone the average relative response to atmospheric ozone levels for each instrument was determined using the colorimetric oxidant analyzer as an arbitrary standard. These responses ranged from 77 percent for the galvanic cell 90 percent for the photometer. The instrument of choice for any given application would seem to be governed by requirements for precision specificity, portability, reliability, and ease of operation.