The Identification and Determination of Airborne Particulates By Means of the Ring Oven Technique
Authors:Philip W West
Institution:Coates Chemical Laboratories, Louisiana State University , Baton Rouge , Louisiana , 70803 , USA
Abstract:The ring oven technique was first introduced as a means for conducting separations and concentrations on filter paper for final spot test analysis. By means of the technique, a complete qualitative scheme of separation and analysis can be made on a single drop of unknown. Recently, the effectiveness of the ring oven as a tool for quantitative analysis has been recognized. The method is particularly attractive for studies of airborne particulates. Samples of airborne particulates can be collected by high volume samplers, tape samplers, electrostatic precipitators, or by other appropriate means. The samples may be put into solution and an aliquot added to filter paper on a ring oven and washed to the ring zone for final identification and estimation. Any necessary separations can normally be carried out during the ring oven operations. A convenient approach for most studies is to collect the samples on tapes and carry out the necessary dissolution, separation, identification, and estimation steps directly on the tape itself. The ring oven methods are usually selective or even specific. The method applies to the microgram to nanogram range and the accuracies are comparable with those obtained by emission spectroscopy, polarography, fluorimetry, and spectrophotometry.