Liquid Entrainment from a Mobile Bed Scrubber
Authors:Seymour Calvert  Shui-Chow Yung  Leslie E Sparks
Institution:1. Air Pollution Technology, Inc.;2. U.S. Environmental Protection Agency
Abstract:Liquid entrainment rate and drop size distribution were measured in the exhaust gas stream from a mobile bed scrubber. The pilot plant scrubber was 46 cm (18 in.) square and was packed with 3.8 cm (1.5 In.) diameter hollow polyethylene spheres to a static depth of 25 cm (10 in.). Entrainment flow rate depends on both gas and liquid rates. At a liquid/gas ratio of 6.7 l/m3 (50 gal/Mcf) and a superficial gas velocity of 2.6 m/sec (8.5 ft/sec) the entrainment flow rate was 0.0064 l/m3 (0.05 gal/Mcf) and at 3.75 m/sec (12.3 ft/sec) it was 0.031 l/m3 (0.23 gal/Mcf). The mass median drop diameter was about 400 nm at a liquid/gas ratio of 6.7 l/m3. The drop size distribution appears to be bimodal. Dye impregnated paper and cascade impactor techniques were used to measure drop size.