首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effects of Operational Factors on Pollutant Emission Rates from Residential Gas Appliances
Authors:S M Relwani  D J Moschandreas  I H Billick
Institution:1. IIT Research Institute , Chicago , Illinois , USA;2. Gas Research Institute , Chicago , Illinois , USA
Abstract:The NO, NO2, and CO emissions from residential gas combustion appliances contribute to indoor air pollution. The work described investigated the impact of various unvented gas appliances designs and/or operational factors on pollutant emission rates. All experiments were performed in a 1150 ft3 (32.56 m3) all aluminum chamber under controlled conditions. Results are presented for the effect of the following factors on emission rates: 1) appliance type and/or design, 2) primary aeration level, 3) firing rate (fuel input rate), 4) chamber humidity, and 5) time dependence of emission rates. It is concluded that primary aeration level has the largest impact on pollutant emission rates of range-top burners, followed in turn by firing rate, appliance type, chamber humidity, and time dependence of emission rate.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号