Quench Tower Particulate Emissions |
| |
Authors: | Gerald L. Ertel |
| |
Affiliation: | Environmental Engineer , Dominion Foundries and Steel, Limited , Hamilton , Ontario , Canada |
| |
Abstract: | Particulate emission sampling was conducted at Dofasco’s No. 2 Coke Want Quench Tower in August 1977. The sampling was performed by York Research Corporation using EPA developed quench tower sampling techniques. Particulate emissions averaged 0.245 lb/ton of coal over 17 tests. The mist eliminator in the tower consists of two rows of zig-zag baffles inclined at 20° from the vertical. Particle size data indicated that the majority of the particulate emissions were less than 10 microns in diameter. A mathematical model was used to predict the effect of particle size and gas velocity on collection efficiency. Pressure drop and re-entrainment are two restrictions which are considered in baffle design. Quench towers are the largest contributor to Dofasco’s allowable off-the-property suspended particulate impingement concentration. |
| |