首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Mean Drop Size in a Full Scale Venturi Scrubber via Transmissometer
Authors:RH Boll  LR Fiais  PW Maurer  WL Thompson
Institution:1. Babcock &2. Wilcox Company , Alliance , Ohio , USA
Abstract:This paper describes the construction of and the data obtained from a light transmissometer capable of making mean drop size measurements within about ±15%. The experimental venturi had a throat flow cross-section of 12 in. by 14 in. and overall length in the flow direction was 15 ft. It was found that the Nukiyama-Tanasawa equation gave accurate estimates of Sauter mean drop size only for a throat velocity of 150 ft/sec.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏