首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Laboratory and Field Evaluation of the Controlled Condensation System for S03 Measurements in Flue Gas Streams
Authors:Ray F Maddalone  Steve F Newton  Richard G Rhudy  Robert M Statnick
Institution:1. TRW Defense and Space Systems Group;2. Tennessee Valley Authority;3. Electric Power Research Institute;4. U.S. Environmental Protection Agency
Abstract:The study reported by this paper involves the use of the Controlled Condensation System (Goksoyr/Ross Coil) for flue gas S03 measurements in both the laboratory and the field, under low and high mass loadings. The Controlled Condensation System cools the flue gas to below the dewpoint of H2S04 but above the H20 dewpoint. The resulting aerosol is collected either on the coil walls or on the back-up glass frit. The laboratory recovery of the H2S04 in streams of varying S02, H20, and H2S04 content was found to be 95 ± 6%. A new quartz filter holder was designed to meet the filtration problems encountered in collecting S03 from particle laden flue gas streams. This quartz system, when heated to above 250°C, quantitatively passed the H2S04 into the condensation coil. Later studies with this filter system preloaded with fly ash equivalent to a mass loading of 1.3 g/m3 yielded a 80-85% recovery of H2S04. The laboratory system was simultaneously tested at a 150 megawatt, pulverized coal-fired power plant prior to and after a wet limestone FGD. The inlet grain loading to the FGD ranged from 0.06 g/m3 to 11.4 g/m3 with S02 concentrations as high as 4000 ppm. The average inlet H2S04 value was 8.3 ppm and the outlet from the FGD was 3.1 ppm. The source fluctuation value was determined to be ±65%.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号